529 research outputs found

    Direct Telemetry Access

    Get PDF
    Fine-grained network telemetry is becoming a modern datacenter standard and is the basis of essential applications such as congestion control, load balancing, and advanced troubleshooting. As network size increases and telemetry gets more fine-grained, there is a tremendous growth in the amount of data needed to be reported from switches to collectors to enable network-wide view. As a consequence, it is progressively hard to scale data collection systems.We introduce Direct Telemetry Access (DTA), a solution optimized for aggregating and moving hundreds of millions of reports per second from switches into queryable data structures in collectors' memory. DTA is lightweight and it is able to greatly reduce overheads at collectors. DTA is built on top of RDMA, and we propose novel and expressive reporting primitives to allow easy integration with existing state-of-the-art telemetry mechanisms such as INT or Marple.We show that DTA significantly improves telemetry collection rates. For example, when used with INT, it can collect and aggregate over 400M reports per second with a single server, improving over the Atomic MultiLog by up to 16x

    Survival, Reproduction and Calcification of Three Benthic Foraminiferal Species in Response to Experimentally Induced Hypoxia

    Get PDF
    An experiment was conducted to test the survival rates, growth (calcification), and reproduction capacities of three benthic foraminiferal species (Ammonia tepida, Melonis barleeanus and Bulimina marginata) under strongly oxygen-depleted conditions alternating with short periods of anoxia. Protocols were determined to use accurate methods (1) to follow oxygen concentrations in the aquaria (continuously recorded using microsensors), (2) to distinguish live foraminifera (fluorogenic probe), (3) to determine foraminiferal growth (calcein-marked shells and automatic measurement of the shell size). Our results show a very high survival rate, and growth of A. tepida and M. barleeanus in all experimental conditions, suggesting that survival and growth are not negatively impacted by hypoxia. Unfortunately, no reproduction was observed for these species, so that we cannot draw firm conclusions on their ability to reproduce under hypoxic/anoxic conditions. The survival rates of Bulimina marginata are much lower than for the other two species. In the oxic treatments, the presence of juveniles is indicative of reproductive events, which can explain an important part of the mortality. The absence of juveniles in the hypoxic/anoxic treatments could indicate that these conditions inhibit reproduction. Alternatively, the perceived absence of juveniles could also be due to the fact that the juveniles resulting from reproduction (causing similar mortality rates as in the oxic treatments) were not able to calcify, and remained at a propagule stage. Additional experiments are needed to distinguish these two options

    How simple can a model of an empty viral capsid be? Charge distributions in viral capsids

    Full text link
    We investigate and quantify salient features of the charge distributions on viral capsids. Our analysis combines the experimentally determined capsid geometry with simple models for ionization of amino acids, thus yielding the detailed description of spatial distribution for positive and negative charge across the capsid wall. The obtained data is processed in order to extract the mean radii of distributions, surface charge densities and dipole moment densities. The results are evaluated and examined in light of previously proposed models of capsid charge distributions, which are shown to have to some extent limited value when applied to real viruses.Comment: 10 pages, 10 figures; accepted for publication in Journal of Biological Physic

    Design and tests of high sensitivity NTD Ge thermometers for the Planck-High Frequency Instrument

    Get PDF
    The High Frequency Instrument of Planck needs high sensitivity semi-conductors at low temperature to monitor the temperature of the bolometer plate. We have modeled such thermometers by using a semi-analytical approach of Anderson insulators, taking into account both the electrical field and the electron/phonon decoupling effects. The optimized design uses convenient NTD Ge material and has larger dimension than the initial design. The first measurements of these optimized thermometers showed a significant thermal de-coupling effect due to Kapitza resistance with its mechanical support. Nevertheless, a sensitivity of about 8 nK.Hz^(–0.5), not far from the predicted one, was obtained. The noise spectrum of the thermometer was flat down to 1 Hz, dominated at lower frequency by the thermal fluctuations

    Mafb lineage tracing to distinguish macrophages from other immune lineages reveals dual identity of Langerhans cells

    Get PDF
    Current systems for conditional gene deletion within mouse macrophage lineages are limited by ectopic activity or low efficiency. In this study, we generated a Mafb-driven Cre strain to determine whether any dendritic cells (DCs) identified by Zbtb46-GFP expression originate from a Mafb-expressing population. Lineage tracing distinguished macrophages from classical DCs, neutrophils, and B cells in all organs examined. At steady state, Langerhans cells (LCs) were lineage traced but also expressed Zbtb46-GFP, a phenotype not observed in any other population. After exposure to house dust mite antigen, Zbtb46-negative CD64(+) inflammatory cells infiltrating the lung were substantially lineage traced, but Zbtb46-positive CD64(−) cells were not. These results provide new evidence for the unique identity of LCs and challenge the notion that some inflammatory cells are a population of monocyte-derived DCs
    corecore